7920095-00
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
7920095-00
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Maximum Voltage Drop Per Function1.15 volts ac 2nd radio interference 
- 
                                    Power Line Frequency Rating Per Function In Hertz400.0 2nd radio interference 
- 
                                    Power Line Frequency Rating Per Function In Hertz400.0 3rd radio interference 
- 
                                    Operating Temp Range-46.0/+71.0 deg celsius 
- 
                                    Source Impedance Rating Per Function50.0 ohms 4th radio interference 
- 
                                    Power Line Frequency Rating Per Function In Hertz400.0 4th radio interference 
- 
                                    Body Height8.000 inches nominal 
- 
                                    Load Impedance Per Function50.0 ohms 2nd radio interference 
- 
                                    Body Surface Treatmenttin 
- 
                                    Operating Voltage Rating And Type Per Function115.0 volts ac 1st radio interference 1st function 
- 
                                    Operating Current Rating Per Function In Amps75.0 3rd radio interference 
- 
                                    Operating Current Rating Per Function In Amps75.0 4th radio interference 
- 
                                    Operating Voltage Rating And Type Per Function115.0 volts ac 3rd radio interference 3rd function 
- 
                                    Mounting Facility Screw Thread Series Designatorunf 
- 
                                    Source Impedance Rating Per Function50.0 ohms 2nd radio interference 
- 
                                    Principal Circuitry Type Per Functioninductance-capacitance 4th radio interference 
- 
                                    Inclosure Typehermetically sealed 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length7.000 inches nominal 
- 
                                    Maximum Voltage Drop Per Function1.15 volts ac 4th radio interference 
- 
                                    Functional Terminal Type And Quantity4 threaded stud output 2nd function 
- 
                                    Nominal Thread Size0.250 inches 
- 
                                    Load Impedance Per Function50.0 ohms 1st radio interference 
- 
                                    Operating Voltage Rating And Type Per Function115.0 volts ac 4th radio interference 4th function 
- 
                                    Source Impedance Rating Per Function50.0 ohms 3rd radio interference 
- 
                                    Features Providednut and washer 
- 
                                    Power Line Frequency Rating Per Function In Hertz400.0 1st radio interference 
- 
                                    Principal Circuitry Type Per Functioninductance-capacitance 1st radio interference 
- 
                                    Operating Current Rating Per Function In Amps75.0 2nd radio interference 
- 
                                    Unpackaged Unit Weight30.000 pounds 
- 
                                    Mounting Facility Type And Quantity12 threaded stud 
- 
                                    Principal Circuitry Type Per Functioninductance-capacitance 3rd radio interference 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width3.000 inches nominal 
- 
                                    Load Impedance Per Function50.0 ohms 4th radio interference 
- 
                                    Overall Length20.000 inches nominal 
- 
                                    Maximum Temp Rise40.0 deg celsius 
- 
                                    Operating Current Rating Per Function In Amps75.0 1st radio interference 
- 
                                    Operating Voltage Rating And Type Per Function115.0 volts ac 2nd radio interference 2nd function 
- 
                                    Maximum Voltage Drop Per Function1.15 volts ac 3rd radio interference 
- 
                                    Source Impedance Rating Per Function50.0 ohms 1st radio interference 
- 
                                    Maximum Dielectric Withstanding Dc Voltage500.0 volts at sea level 
- 
                                    Vibration Resistance Range In Hertz+10.0/+500.0 
- 
                                    Style Designatorrectangular terminal/terminals on opposite surfaces 
- 
                                    Load Impedance Per Function50.0 ohms 3rd radio interference 
- 
                                    Special Featuresfour filtered functions 
- 
                                    Functional Terminal Type And Quantity4 threaded stud input 1st function 
- 
                                    Full Load Minimum Insertion Loss At Specified Frequency In Decibels90.0 and 3.0 and 40.0 and 60.0 and 20.0 and 90.0 
- 
                                    Full Load Insertion Loss Frequencies In Megahertz0.0 and 0.2 and 0.6 and 0.1 and 1.0 and 1000.0 
- 
                                    Maximum Voltage Drop Per Function1.15 volts ac 1st radio interference 
- 
                                    Body Width4.000 inches nominal 
- 
                                    Principal Circuitry Type Per Functioninductance-capacitance 2nd radio interference 
- 
                                    Body Materialmetal 
- 
                                    Body Length17.500 inches nominal 