M55629/22RNRNRN
Circuit Breakers
CIRCUIT BREAKER
M55629/22RNRNRN
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
-
Mounting Surface To Terminal End Distance
2.232 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations
-
Switch Terminal Type
pin
-
Inclosure Protection Type For Which Designed
shock resistant and hermetically sealed and vibration resistant
-
Auxiliary Switch Function And Quantity
1 alarm
-
Thread Series Designator
un
-
Terminal Type And Quantity
6 tab w/screw
-
Nonturn Device Radius
0.656 inches nominal
-
Switch Location And Position Designation
internal at pole one
-
Nonturn Device Length
0.130 inches nominal
-
Thread Pitch Diameters
+0.4752/+0.4787 inches
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Body Width
2.265 inches maximum
-
Manual Actuator Type And Quantity
1 toggle
-
Frequency In Hertz
60.0 all locations
-
Bushing Length
0.625 inches nominal
-
Specification/Standard Data
81349-mil-c-55629/22 government specification
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
-
Reset Method
manual
-
Nominal Thread Size
0.500 inches
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Nonturn Device Location
at 12 oclock
-
Switch Current Rating And Type In Amps
10.0 ac and 1.0 dc
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
~1
data on certain environmental and performanc
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Actuator Position Designation
at pole two
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.160 minimum at 200 pct all locations and 1.600 maximum at 200 pct all locations
-
Switch Contact Arrangement
single pole, double throw
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Nonturn Device Diameter
0.151 inches minimum and 0.161 inches maximum