MIL-C-55629/22

Circuit Breakers

CIRCUIT BREAKER

MIL-C-55629/22

5925-01-337-4928

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Switch Terminal Type

    pin

  • Inclosure Protection Type For Which Designed

    shock resistant and hermetically sealed and vibration resistant

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Thread Series Designator

    un

  • Terminal Type And Quantity

    6 tab w/screw

  • Nonturn Device Radius

    0.656 inches nominal

  • Switch Location And Position Designation

    internal at pole one

  • Nonturn Device Length

    0.130 inches nominal

  • Thread Pitch Diameters

    +0.4752/+0.4787 inches

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Body Width

    2.265 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Bushing Length

    0.625 inches nominal

  • Specification/Standard Data

    81349-mil-c-55629/22 government specification

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Reset Method

    manual

  • Nominal Thread Size

    0.500 inches

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Nonturn Device Location

    at 12 oclock

  • Switch Current Rating And Type In Amps

    10.0 ac and 1.0 dc

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • ~1

    data on certain environmental and performanc

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Position Designation

    at pole two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.160 minimum at 200 pct all locations and 1.600 maximum at 200 pct all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...