4081-44931-001
Circuit Breakers
CIRCUIT BREAKER
4081-44931-001
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant and salt water resistant
 - 
                                    
Pole Quantity
1
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location
 - 
                                    
Thread Pitch Diameters
+0.4752/+0.4787 inches
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Frequency In Hertz
50.0 single location or 60.0 single location
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
 - 
                                    
Terminal Type And Quantity
2 tab, solder lug
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
 - 
                                    
Mounting Surface To Terminal End Distance
2.232 inches maximum
 - 
                                    
Body Style
single pole type
 - 
                                    
Thread Series Designator
un
 - 
                                    
Nonturn Device Radius
0.656 inches nominal
 - 
                                    
Case Material
plastic
 - 
                                    
Nonturn Device Length
0.130 inches nominal
 - 
                                    
Nonturn Device Location
at 12 oclock
 - 
                                    
Bushing Length
0.612 inches nominal
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct single location and 150.000 maximum at 200 pct single location
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Trip Release Method
magnetic single location
 - 
                                    
Special Handling Feature
magnetic
 - 
                                    
Reset Method
manual
 - 
                                    
Nominal Thread Size
0.500 inches
 - 
                                    
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Body Width
0.750 inches nominal
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Body Length
2.000 inches nominal
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    