LAL36250WB

Circuit Breakers

CIRCUIT BREAKER

LAL36250WB

5925-01-342-5703

5925 - Circuit Breakers

Square D Co

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    2.000 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +1250.0/+2500.0 ac all locations

  • Arc Quenching Method

    magnetic blowout

  • Boss Height

    1.970 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    18000.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    250.0 amperes ac all locations and 250.0 amperes dc all locations

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 compression

  • Center To Center Distance Between Terminals Parallel To Length

    9.250 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Style

    multipole-single actuator type

  • Actuator Position Designation

    at pole two

  • Trip Release Method

    thermal-magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    9.250 inches nominal

  • Body Length

    14.750 inches nominal

  • Body Width

    6.000 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Storage Type

    general purpose warehouse

  • Unthreaded Mounting Hole Diameter

    0.196 inches nominal

  • Features Provided

    adjustable trip release

  • Reset Method

    manual

  • Inclosure Protection Type For Which Designed

    dustproof

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Trip Release Characteristic

    instantaneous all locations

  • Fragility Factor

    moderately rugged

  • Body Height

    4.370 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...