MIL-PRF-39016/24

Relays and Solenoids

RELAY,ELECTROMAGNETIC

MIL-PRF-39016/24

5945-01-344-3120

5945 - Relays and Solenoids

Military Specifications

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-r-39016 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performanc

  • Winding Dc Resistance Rating

    500.0 ohms nominal single winding

  • Specification/Standard Data

    81349-mil-r-39016/24 government specification

  • Duty Type

    continuous

  • Time Delay

    0.002 seconds maximum fixed operate time

  • Features Provided

    coil voltage suppression and polarized

  • Fragility Factor

    moderately rugged

  • Overall Width

    0.370 inches maximum

  • Storage Type

    general purpose warehouse

  • Criticality Code Justification

    feat

  • Nonpile-Up Main Contact Arrangement

    2 pole, double throw, one position momentary

  • Environmental Protection

    hermetic

  • Main Contact Load Current Rating At Maximum Rated Voltage

    500.0 milliamperes ac resistive load and 1.0 amperes dc resistive load

  • Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    11 terminal single mounting facility

  • Winding Quantity

    1

  • Main Contact Load Current Rating At Maximum Rated Voltage

    100.0 milliamperes dc lamp load

  • Terminal Type And Quantity

    11 pin all functions

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Overall Height

    0.398 inches maximum

  • Special Features

    failure rate 0.1 percent per 10,000 cycles

  • Time Delay

    0.004 seconds maximum fixed release time

  • Purpose For Which Designed

    general

  • Coil Quantity

    1

  • Main Contact Load Current Rating At Maximum Rated Voltage

    200.0 milliamperes dc inductive load

  • Cubic Measure

    0.054 cubic inches

  • Operating Voltage Rating And Type At Specified Temp

    12.0 volts dc 25 deg celsius single winding

  • Overall Length

    0.370 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...