52299-1

Circuit Breakers

CIRCUIT BREAKER

52299-1

5925-01-345-4975

5925 - Circuit Breakers

Hamilton Standard Electronics

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc second location

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes dc second location

  • Body Length

    1.562 inches maximum

  • Thread Series Designator

    unef

  • Body Width

    1.281 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Case Material

    plastic

  • Actuator Position Designation

    between pole one and two

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc second location

  • Body Style

    multipole-single actuator type

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac first location

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Terminal Type And Quantity

    4 wire hook

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Trip Release Method

    magnetic all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac first location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.950 maximum at 200 pct first location

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Frequency In Hertz

    400.0 first location

  • Reset Method

    manual

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Special Handling Feature

    magnetic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct first location and 0.060 minimum at 200 pct second location and 0.600 maximum at 200 pct second location

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...