MIL-S-24236/20
Switches
SWITCH,THERMOSTATIC
MIL-S-24236/20
SWITCH,THERMOSTATIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Hazardous Locations/Environmental Protection
vibration resistant
-
Body Diameter
0.660 inches maximum
-
Contact Adjustability
actuation point not adjustable and deactuation point not adjustable
-
Mounting Slot Width
0.094 inches minimum and 0.114 inches maximum
-
Style Designator
disc
-
Distance Between Mounting Facility Centers
0.930 inches minimum and 0.944 inches maximum
-
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action
-
Mounting Method
bracket and slot
-
Overall Height
3.600 inches maximum
-
Contact Load Current Rating
0.5 amperes lamp load first voltage
-
Features Provided
hermetically sealed case
-
Terminal Type
tab, solder lug
-
Temp Sensing Element Type
internal sensor
-
Test Data Document
81349-mil-s-24236 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Contact Action Stimulus
increase
-
Operating Temp Rating
-10.0 deg fahrenheit minimum and 250.0 deg fahrenheit maximum
-
Mounting Facility Pattern
two position in-line
-
Special Features
mtg bracket is 1.510 in. max lg
-
Contact Voltage Rating In Volts
28.0 dc at sea level second voltage
-
Specification/Standard Data
81349-mil-s-24236/20 government specification
-
Contact Stimulus Rating
21.00 deactuation point minimum degrees fahrenheit and 25.00 actuation point nominal degrees fahrenheit and 23.00 deactuation point maximum degrees fahrenheit
-
Overall Length
0.834 inches nominal
-
Frequency In Hertz
60.0 first voltage
-
Contact Voltage Rating In Volts
115.0 ac at sea level first voltage
-
Media For Which Designed
gas or liquid
-
Contact Load Current Rating
1.5 amperes inductive load first voltage and 1.0 amperes inductive load second voltage and 2.0 amperes resistive load second voltage and 2.0 amperes resistive load first voltage and 1.0 amperes lamp load second voltage
-
~1
data on certain environmental and performanc
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods