AP12-24241-4

Circuit Breakers

CIRCUIT BREAKER

AP12-24241-4

5925-01-354-6084

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc first location

  • Inclosure Protection Type For Which Designed

    dustproof and shock resistant and hermetically sealed and vibration resistant and fungus resistant and corrosion resistant

  • Actuator Position Designation

    between pole one and two

  • Mounting Facility Type And Quantity

    2 threaded hole and 1 threaded bushing w/panel seal

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Body Length

    1.562 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Trip Release Characteristic

    instantaneous second location

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc all locations

  • Body Width

    1.281 inches maximum

  • Test Data Document

    13973-865528 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Features Provided

    high inrush protection

  • Thread Series Designator

    unc and unef

  • Unpackaged Unit Weight

    4.000 ounces

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Body Style

    multipole-single actuator type

  • Mounting Surface To Terminal End Distance

    1.628 inches maximum

  • Terminal Type And Quantity

    4 wire hook

  • Trip Release Characteristic

    time delay first location

  • Nominal Thread Size

    0.138 inches and 0.375 inches

  • Trip Release Method

    magnetic all locations

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    100.0 milliamperes dc second location

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct first location and 0.950 maximum at 200 pct first location

  • Reset Method

    manual

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...