AP12-24241-4
Circuit Breakers
CIRCUIT BREAKER
AP12-24241-4
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc first location
-
Inclosure Protection Type For Which Designed
dustproof and shock resistant and hermetically sealed and vibration resistant and fungus resistant and corrosion resistant
-
Actuator Position Designation
between pole one and two
-
Mounting Facility Type And Quantity
2 threaded hole and 1 threaded bushing w/panel seal
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Body Length
1.562 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Trip Release Characteristic
instantaneous second location
-
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc all locations
-
Body Width
1.281 inches maximum
-
Test Data Document
13973-865528 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Features Provided
high inrush protection
-
Thread Series Designator
unc and unef
-
Unpackaged Unit Weight
4.000 ounces
-
Manual Actuator Type And Quantity
1 toggle
-
Case Material
metal
-
Body Style
multipole-single actuator type
-
Mounting Surface To Terminal End Distance
1.628 inches maximum
-
Terminal Type And Quantity
4 wire hook
-
Trip Release Characteristic
time delay first location
-
Nominal Thread Size
0.138 inches and 0.375 inches
-
Trip Release Method
magnetic all locations
-
Thread Quantity Per Inch
32
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc all locations
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Continuous Load Current Rating Per Pole
100.0 milliamperes dc second location
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Storage Type
general purpose warehouse
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct first location and 0.950 maximum at 200 pct first location
-
Reset Method
manual
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods