M55629/21UMUM

Circuit Breakers

CIRCUIT BREAKER

M55629/21UMUM

5925-01-357-7024

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-55926 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Mounting Facility Type And Quantity

    2 threaded hole and 1 threaded bushing w/panel seal

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Body Width

    1.515 inches maximum

  • Special Handling Feature

    fragile

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Thread Series Designator

    unc and un

  • Case Material

    plastic

  • ~1

    data on certain environmental and performanc

  • Fragility Factor

    moderately rugged

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Style

    multipole-single actuator type

  • Nominal Thread Size

    0.138 inches and 0.500 inches

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Specification/Standard Data

    81349-mil-c-55629/21 government specification

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Actuator Position Designation

    at pole two

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Bushing Length

    0.115 inches minimum and 0.145 inches maximum

  • Thread Quantity Per Inch

    32

  • Switch Current Rating And Type In Amps

    10.0 ac and 1.0 dc

  • Terminal Type And Quantity

    4 tab w/screw

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Body Length

    2.000 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Switch Location And Position Designation

    internal at pole two

  • Storage Type

    general purpose warehouse

  • Reset Method

    manual

  • Pole Quantity

    2

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Switch Terminal Type

    tab, solder lug

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...