Technical Characteristics
- 
                                    Overall Length4.400 inches maximum 
- 
                                    Mounting Methodbase and unthreaded hole 
- 
                                    Overall Width1.470 inches minimum and 1.530 inches maximum 
- 
                                    Terminal Typeconnector, receptacle 
- 
                                    Contact Stimulus Rating68.00 actuation point nominal pounds per square inch gage and 23.00 deactuation point nominal pounds per square inch gage 
- 
                                    Hazardous Locations/Environmental Protectionvibration resistant 
- 
                                    Overall Height1.470 inches minimum and 1.530 inches maximum 
- 
                                    Unthreaded Mounting Hole Diameter0.208 inches minimum and 0.214 inches maximum 
- 
                                    Contact Voltage Rating In Volts240.0 ac at sea level single voltage 
- 
                                    Contact Adjustabilityactuation point not adjustable and deactuation point not adjustable 
- 
                                    Special Featuresconnector receptacle with cable is 19.000 lg. 
- 
                                    Proof Pressure150.00 pounds per square inch gage 
- 
                                    Operating Temp Rating0.0 deg celsius minimum and 65.0 deg celsius maximum 
- 
                                    Distance Between Mounting Facility Centers1.115 inches minimum and 1.135 inches maximum 
- 
                                    Features Providedhermetically sealed case 
- 
                                    Style Designatorrectangular 
- 
                                    Media For Which Designedgas or liquid 
- 
                                    Nonpile-Up Contact Arrangement1 pole, double throw, one position momentary 
- 
                                    Pressure Switch Typegage 
- 
                                    Sensing Element Burst Pressure300.00 pounds per square inch gage 
- 
                                    Mounting Facility Patterntwo position in-line 
- 
                                    Contact Load Current Rating11.0 amperes resistive load single voltage 
- 
                                    Contact Action Stimulusincrease 