MIL-PRF-55629/21

Circuit Breakers

CIRCUIT BREAKER

MIL-PRF-55629/21

5925-01-359-9585

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Switch Terminal Type

    tab, solder lug

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Fragility Factor

    rugged

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.500 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Pole Quantity

    2

  • Reset Method

    manual

  • Nominal Thread Size

    0.500 inches

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Switch Voltage Rating And Type In Volts

    50.0 dc

  • Trip Release Characteristic

    time delay all locations

  • Body Length

    2.000 inches nominal

  • Inclosure Protection Type For Which Designed

    shock resistant and fungus resistant and vibration resistant and salt spray proof and moisture resistant and explosion resistant

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc first location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Terminal Type And Quantity

    4 tab w/screw

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Switch Current Rating And Type In Amps

    2.0 dc

  • Actuator Position Designation

    at pole two

  • Switch Contact Arrangement

    single pole, double throw

  • ~1

    data on certain environmental and performanc

  • Specification/Standard Data

    81349-mil-c-55629/21 government specification

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Bushing Length

    0.625 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes dc second location

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Body Width

    1.515 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Thread Series Designator

    un

  • Switch Location And Position Designation

    internal at pole one

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...