Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Terminal Type And Quantity

    2 wire hook

  • Inclosure Protection Type For Which Designed

    shock resistant and moisture resistant and fungus resistant and vibration resistant and corrosion resistant

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.375 inches

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    1.562 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Body Style

    single pole type

  • Body Width

    0.625 inches maximum

  • Frequency In Hertz

    60.0 single location

  • Special Handling Feature

    fragile

  • Thread Series Designator

    unef

  • Mounting Surface To Terminal End Distance

    1.700 inches maximum

  • Unpackaged Unit Weight

    50.0 grams

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location and 500.0 dc single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct single location and 0.950 maximum at 200 pct single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location and 50.0 dc single location

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...