CD3-Z615-1W

Circuit Breakers

CIRCUIT BREAKER

CD3-Z615-1W

5925-01-382-4381

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct first location and 60.000 maximum at 200 pct first location

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac first location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Internal Trip Release Configuration

    series trip all locations

  • Frequency In Hertz

    47.0 second location or 440.0 second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 all locations

  • Mounting Slot Width

    0.164 inches nominal

  • Manual Actuator Type And Quantity

    3 toggle

  • Unpackaged Unit Weight

    2.000 pounds

  • Mounting Facility Type And Quantity

    3 slot and 6 threaded hole

  • Frequency In Hertz

    47.0 first location or 440.0 first location

  • Case Material

    plastic

  • Trip Release Characteristic

    instantaneous third location

  • Terminal Type And Quantity

    6 threaded stud

  • Body Style

    multipole-multiple actuator type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac second location

  • Trip Release Characteristic

    time delay first location

  • Body Width

    2.072 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct second location and 60.000 maximum at 200 pct second location

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc third location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay second location

  • Center To Center Distance Between Terminals Parallel To Length

    3.547 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    125.0 amperes ac first location

  • Body Height

    2.609 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Body Length

    5.800 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    125.0 amperes ac second location

  • Boss Height

    0.219 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...