MIL-S-24236/1

Switches

SWITCH,THERMOSTATIC

MIL-S-24236/1

5930-01-383-7073

5930 - Switches

Military Specifications

SWITCH,THERMOSTATIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performanc

  • Nonpile-Up Contact Arrangement

    1 pole, single throw, normally open, momentary action

  • Terminal Type

    tab, solder lug

  • Overall Diameter

    0.540 inches minimum and 0.640 inches maximum

  • Mounting Method

    threaded bushing

  • Err Default

    err default

  • Thread Series Designator

    unc single threaded stud

  • Contact Adjustability

    actuation point not adjustable and deactuation point not adjustable

  • Nominal Thread Size

    0.138 inches single threaded stud

  • Operating Temp Rating

    -65.0 deg fahrenheit minimum and 500.0 deg fahrenheit maximum

  • Style Designator

    disc

  • Media For Which Designed

    gas

  • Test Data Document

    81349-mil-s-24236 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Temp Sensing Element Type

    internal sensor

  • Contact Voltage Rating In Volts

    115.0 ac at sea level first voltage

  • Thread Quantity Per Inch

    32 single threaded stud

  • Thread Class

    2a single threaded stud

  • Frequency In Hertz

    60.0 first voltage

  • Specification/Standard Data

    81349-mil-s-24236/1 government specification

  • Contact Stimulus Rating

    110.00 actuation point nominal degrees fahrenheit and 100.00 deactuation point nominal degrees fahrenheit

  • Overall Height

    0.625 inches nominal

  • Contact Load Current Rating

    2.0 amperes resistive load first voltage and 1.0 amperes inductive load first voltage and 500.0 milliamperes lamp load first voltage

  • Contact Load Current Rating

    5.0 amperes resistive load second voltage and 2.5 amperes inductive load second voltage and 1.0 amperes lamp load second voltage

  • Contact Voltage Rating In Volts

    28.0 dc at sea level second voltage

  • Body Height

    0.437 inches maximum

  • Contact Action Stimulus

    increase

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...