87057-014
Circuit Breakers
CIRCUIT BREAKER
87057-014
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct single location and 20.000 maximum at 200 pct single location
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
1.25 amperes ac single location and 1.25 amperes dc single location
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
 - 
                                    
Body Length
1.562 inches maximum
 - 
                                    
Frequency In Hertz
400.0 single location
 - 
                                    
Body Style
single pole type
 - 
                                    
Body Width
0.625 inches maximum
 - 
                                    
Mounting Surface To Terminal End Distance
1.605 inches maximum
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
 - 
                                    
Thread Series Designator
unef
 - 
                                    
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
 - 
                                    
Auxiliary Switch Function And Quantity
1 alarm
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location and 500.0 dc single location
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location and 50.0 dc single location
 - 
                                    
Bushing Length
0.380 inches maximum
 - 
                                    
Switch Location And Position Designation
internal at pole one
 - 
                                    
Mounting Facility Type And Quantity
2 threaded bushing w/panel seal
 - 
                                    
Switch Contact Arrangement
single pole, double throw
 - 
                                    
Terminal Type And Quantity
2 wire hook
 - 
                                    
Switch Terminal Type
tab, solder lug
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Nominal Thread Size
0.375 inches
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Trip Release Method
magnetic all locations
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
 - 
                                    
Pole Quantity
1
 - 
                                    
Case Material
metal
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    