MIL-C-55629/21
Circuit Breakers
CIRCUIT BREAKER
MIL-C-55629/21
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Reset Method
manual
-
Nominal Thread Size
0.500 inches
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Switch Location And Position Designation
internal at pole two
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations
-
Terminal Type And Quantity
4 tab w/screw
-
Switch Current Rating And Type In Amps
10.0 ac and 1.0 dc
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Trip Release Method
magnetic all locations
-
Actuator Position Designation
at pole two
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Switch Contact Arrangement
single pole, double throw
-
Specification/Standard Data
81349-mil-c-55629/21 government specification
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Manual Actuator Type And Quantity
1 toggle
-
Frequency In Hertz
60.0 all locations
-
Bushing Length
0.625 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
-
Mounting Surface To Terminal End Distance
2.232 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations
-
Body Width
1.515 inches maximum
-
Auxiliary Switch Function And Quantity
1 alarm
-
Thread Series Designator
un
-
Switch Terminal Type
screw
-
~1
data on certain environmental and performanc
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods