209-3-1-65-4-4-6-A

Circuit Breakers

CIRCUIT BREAKER

209-3-1-65-4-4-6-A

5925-01-435-0217

5925 - Circuit Breakers

Vdo Control Systems Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    5.125 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    18.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and

  • Frequency In Hertz

    50.0 or

  • Terminal Type And Quantity

    6 threaded stud

  • Body Width

    3.108 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    3.550 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Boss Height

    0.220 inches nominal

  • Mounting Surface To Terminal End Distance

    3.550 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    3.0 millimeters

  • Thread Pitch In Millimeters

    0.50

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Frequency In Hertz

    60.0 all locations

  • Thread Series Designator

    iso s

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...