M39019/01-210S

Circuit Breakers

CIRCUIT BREAKER

M39019/01-210S

5925-01-445-7826

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performanc

  • Bushing Length

    0.380 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    0.5 amperes ac single location

  • Mounting Surface To Terminal End Distance

    1.700 inches maximum

  • Thread Series Designator

    unef

  • Body Width

    0.625 inches maximum

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Frequency In Hertz

    400.0 single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Body Length

    1.562 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Circuit Protection Type

    overcurrent single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    9.000 maximum at 200 pct single location and 0.500 minimum at 200 pct single location and 0.750 maximum at 400 pct single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Terminal Type And Quantity

    4 screw

  • Actuator Function

    trip-reset

  • Specification/Standard Data

    81349-mil-c-39019/01 government specification

  • Actuator Position Designation

    at pole one

  • Ultimate Trip Time Per Pole In Seconds

    0.200 minimum single location and 7.000 maximum single location

  • Reset Method

    manual

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Trip Release Method

    magnetic single location

  • Test Data Document

    81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...