Technical Characteristics

  • ~1

    type data on certain environmental and performa

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay all locations

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.905 inches maximum

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Circuit Protection Type

    overvoltage all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    1.562 inches maximum

  • Specification/Standard Data

    81349-mil-prf-39019/6 government specification

  • Trip Release Duty Cycle

    continuous all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    800.0 all locations

  • Body Width

    1.937 inches nominal

  • Internal Trip Release Configuration

    series trip w/auxiliary load terminal and remote trip feature all locations

  • Frequency In Hertz

    400.0 all locations

  • Nominal Thread Size

    0.250 inches

  • Terminal Type And Quantity

    6 tab w/screw

  • Mounting Surface To Terminal End Distance

    1.950 inches maximum

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    240.0 ac nominal all locations and 50.0 dc nominal all locations

  • Case Material

    plastic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.060 maximum at 800 pct all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.364 inches minimum and 1.424 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.623 inches nominal

  • Pole Quantity

    3

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc all locations

  • Test Data Document

    81349-mil-prf-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...