MIL-C-5809

Circuit Breakers

CIRCUIT BREAKER

MIL-C-5809

5925-01-473-9032

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Method

    thermal single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Style

    1a single pole type

  • Bushing Length

    0.250 inches nominal

  • Body Width

    0.593 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.500 inches nominal

  • Fragility Factor

    moderately rugged

  • End Item Identification

    spruance class dd (963)

  • Mounting Surface To Terminal End Distance

    1.343 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac and 2500.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.500 minimum at 200 pct and 40.000 maximum at 200 pct single location

  • Criticality Code Justification

    feat

  • Special Features

    weapon system essential

  • Test Data Document

    81349-mil-c-5809 specification

  • Terminal Type And Quantity

    2 tab w/screw

  • Actuator Position Designation

    at pole one

  • Body Length

    0.781 inches maximum

  • Case Material

    plastic

  • Pole Quantity

    1

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    0.5 amperes ac and 0.5 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.438 inches

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Frequency In Hertz

    400.0

  • Unpackaged Unit Weight

    0.055 pounds

  • Thread Series Designator

    un

  • Specification/Standard Data

    96906-ms3320-0.5 government standard

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...