M39019/05-225S

Circuit Breakers

CIRCUIT BREAKER

M39019/05-225S

5925-01-474-6045

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Terminal Type

    tab w/screw

  • Mounting Surface To Terminal End Distance

    1.950 inches maximum

  • Features Provided

    high inrush protection

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.359 inches minimum and 1.389 inches maximum

  • Terminal Type And Quantity

    6 tab w/screw

  • Internal Trip Release Configuration

    relay trip all locations

  • Thread Series Designator

    unef

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    800.0 all locations

  • Body Length

    1.562 inches maximum

  • Frequency In Hertz

    60.0 all locations or 400.0 all locations

  • Body Width

    1.937 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.240 nominal at 400 pct all locations

  • Case Material

    ceramic or mica or plastic

  • Main Contact Tripping Mechanism Type

    nontrip free

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes dc all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic all locations

  • Nominal Thread Size

    0.375 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations and 500.0 dc all locations

  • Trip Release Characteristic

    time delay all locations

  • End Item Identification

    1430-01-418-4396

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Reset Method

    manual

  • Inclosure Protection Type For Which Designed

    salt water resistant and tamperproof and fungus proof

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...