M39019/04-320S
Circuit Breakers
CIRCUIT BREAKER
M39019/04-320S
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
-
Auxiliary Switch Function And Quantity
1 alarm
-
Mounting Surface To Terminal End Distance
1.950 inches maximum
-
Body Width
1.250 inches minimum and 1.281 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.653 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations and 5.0 amperes dc all locations
-
~1
type data on certain environmental and performa
-
Test Data Document
81349-mil-prf-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general
-
Reset Method
manual
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
-
Pole Quantity
2
-
Circuit Protection Type
overcurrent all locations
-
Switch Terminal Type
tab, solder lug
-
Thread Series Designator
unef
-
Frequency In Hertz
400.0 all locations
-
Unpackaged Unit Weight
100.0 grams
-
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
-
Specification/Standard Data
81349-mil-prf-39019/4 government specification
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
between pole one and two
-
Manual Actuator Type And Quantity
1 toggle
-
Case Material
metal
-
Body Style
multipole-single actuator type
-
Switch Contact Arrangement
single pole, double throw
-
Trip Release Method
magnetic all locations
-
Special Features
high inrush version; screw terminals with insulating block
-
Body Length
1.531 inches minimum and 1.562 inches maximum
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.375 inches
-
Mounting Facility Type And Quantity
thd bushing w/panel seal
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 50.0 dc all locations
-
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations and 500.0 dc all locations
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches minimum and 0.906 inches maximum
-
Terminal Type And Quantity
4 screw
-
Internal Trip Release Configuration
series trip all locations
-
End Item Identification
ok-644(v)3/fc
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations
-
Switch Location And Position Designation
internal at pole two
-
Storage Type
general purpose warehouse
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods