A68C-10

Circuit Breakers

CIRCUIT BREAKER

A68C-10

5925-01-503-7845

5925 - Circuit Breakers

Crane Carrier Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    1000.0 single location

  • Ultimate Trip Time Per Pole In Seconds

    0.150 minimum single location and 0.780 maximum single location

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Style

    single pole type

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location and 10.0 amperes dc single location

  • Frequency In Hertz

    60.0 single location

  • Thread Series Designator

    unef

  • Mounting Facility Type And Quantity

    1 threaded stud

  • Body Width

    0.560 inches nominal

  • Bushing Length

    0.500 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 50.0 dc single location

  • Thread Quantity Per Inch

    28

  • Case Material

    plastic

  • Actuator Function

    reset

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 1000 pct single location and 0.780 maximum at 1000 pct single location

  • Manual Actuator Type And Quantity

    1 push button

  • Body Length

    1.380 inches nominal

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Surface To Terminal End Distance

    1.660 inches nominal

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • End Item Identification

    nsn 2320-01-452-5579, truck tractor

  • Part Name Assigned By Controlling Agency

    circuit breaker, manual re-set, 10 amp

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    0.840 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...