AP-7-1-52-203

Circuit Breakers

CIRCUIT BREAKER

AP-7-1-52-203

5925-01-507-7873

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    2 tab w/screw

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct single location and 6.000 maximum at 200 pct single location

  • End Item Identification

    10 mrt rib (rigid inflatable boat)

  • Bushing Length

    0.380 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Pole Quantity

    1

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Cubic Measure

    2.885 cubic inches

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Length

    1.562 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Body Style

    single pole type

  • Body Width

    0.625 inches maximum

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Special Handling Feature

    magnetic

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant and hermetically sealed

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...