MS25361-C50V

Circuit Breakers

CIRCUIT BREAKER

MS25361-C50V

5925-01-508-0411

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    1.438 inches nominal

  • Case Material

    metal

  • Specification/Standard Data

    96906-ms25361 government standard

  • Thread Series Designator

    unc

  • Test Data Document

    81349-mil-c-5809 specification

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct and 65.000 maximum at 200 pct single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Method

    thermal single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac and 6000.0 dc single location

  • Thread Quantity Per Inch

    32

  • Iii Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Mounting Surface To Terminal End Distance

    2.250 inches nominal

  • Iii End Item Identification

    rq-4a

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Terminal Type And Quantity

    2 screw

  • Manufacturers Code

    81349

  • Definitive Government Spec/Std Reference

    ms25361-c50v

  • Frequency In Hertz

    400.0 single location

  • Special Features

    random vibration level/high vibration capability

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Inclosure Protection Type For Which Designed

    moisture resistant and explosion resistant

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac and 28.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac and 50.0 amperes dc single location

  • Pole Quantity

    1

  • Body Width

    0.750 inches maximum

  • Body Length

    2.189 inches maximum

  • Bushing Length

    0.250 inches nominal

  • Body Style

    7a single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...