                                    Body Style1b multipole-single actuator type 
- 
                                    Bushing Length0.390 inches minimum and 0.410 inches maximum 
- 
                                    Body Width1.365 inches minimum and 1.385 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.095 inches minimum and 1.155 inches maximum 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac and 50.0 dc all locations 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current1.000 minimum at 200 pct and 15.000 maximum at 200 pct all locations 
- 
                                    Frequency In Hertz50.0 or 60.0 all locations 
- 
                                    Terminal Type And Quantity4 tab, solder lug 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.615 inches minimum and 0.635 inches maximum 
- 
                                    Mounting Surface To Terminal End Distance1.930 inches minimum and 1.990 inches maximum 
- 
                                    Pole Quantity2 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes dc all locations 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity1 push-pull 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Thread Series Designatorunef 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    