583-G111-K1M1-A1S1U-7.5A

Circuit Breakers

CIRCUIT BREAKER

583-G111-K1M1-A1S1U-7.5A

5925-01-523-1915

5925 - Circuit Breakers

Oakland Industries Ltd

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    iso m

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

  • Center To Center Distance Between Terminals Parallel To Length

    12.8 millimeters nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    45.0 millimeters nominal

  • Reset Method

    manual

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac all locations and 28.0 dc all locations

  • Inclosure Protection Type For Which Designed

    fungus proof and shockproof and vibrationproof

  • Thread Pitch In Millimeters

    1.25

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Manual Actuator Type And Quantity

    1 push button

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac all locations and 6000.0 dc all locations

  • End Item Identification

    alofts sonar system, model 980 (v1)

  • Center To Center Distance Between Terminals Parallel To Width

    15.0 millimeters nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Height

    38.0 millimeters nominal

  • Actuator Position Designation

    at pole two

  • Bushing Length

    6.5 millimeters nominal

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Body Length

    19.5 millimeters nominal

  • Nominal Thread Size

    12.0 millimeters

  • Special Features

    black push button

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    6 screw

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac all locations and 7.5 amperes dc all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 10.000 maximum at 200 pct all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...