M55629/3-XRXR
Circuit Breakers
CIRCUIT BREAKER
M55629/3-XRXR
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
data on certain environmental and performance re
-
Nominal Thread Size
0.138 inches
-
Main Contact Tripping Mechanism Type
trip free
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc second location
-
Specification/Standard Data
81349 - mil-prf-55629/3 government specification
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.719 inches minimum and 0.781 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.130 minimum at 200 pct first location and 1.600 maximum at 200 pct first location
-
Manual Actuator Type And Quantity
2 toggle
-
Boss Height
0.109 inches minimum and 0.171 inches maximum
-
Terminal Type And Quantity
4 threaded stud
-
Body Width
1.469 inches minimum and 2.531 inches maximum
-
External Actuator Linkage Arrangement
one and two linked
-
Nondefinitive Spec/Std Data
-55629/3-410 reference number
-
Case Material
plastic
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Length
1.660 inches minimum and 1.960 inches maximum
-
Circuit Protection Type
overcurrent all locations
-
Inclosure Protection Type For Which Designed
dustproof
-
Pole Quantity
2
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.046 inches minimum and 2.078 inches maximum
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Mounting Facility Type And Quantity
4 threaded hole
-
Mounting Surface To Terminal End Distance
2.522 inches minimum and 2.553 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc second location
-
End Item Identification
nsn 5820-01-504-8870, radio set group
-
Thread Quantity Per Inch
32
-
Center To Center Distance Between Terminals Parallel To Width
0.719 inches minimum and 0.781 inches maximum
-
Frequency In Hertz
60.0 first location
-
Arc Quenching Method
air
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Body Length
2.479 inches minimum and 2.510 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac all locations and 35.0 amperes dc all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Test Data Document
mil-prf-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods