MIL-PRF-55629/3

Circuit Breakers

CIRCUIT BREAKER

MIL-PRF-55629/3

5925-01-537-3147

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performance re

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc second location

  • Specification/Standard Data

    81349 - mil-prf-55629/3 government specification

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct first location and 1.600 maximum at 200 pct first location

  • Manual Actuator Type And Quantity

    2 toggle

  • Boss Height

    0.109 inches minimum and 0.171 inches maximum

  • Terminal Type And Quantity

    4 threaded stud

  • Body Width

    1.469 inches minimum and 2.531 inches maximum

  • External Actuator Linkage Arrangement

    one and two linked

  • Nondefinitive Spec/Std Data

    -55629/3-410 reference number

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Mounting Surface To Terminal End Distance

    2.522 inches minimum and 2.553 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc second location

  • End Item Identification

    nsn 5820-01-504-8870, radio set group

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Width

    0.719 inches minimum and 0.781 inches maximum

  • Frequency In Hertz

    60.0 first location

  • Arc Quenching Method

    air

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Body Length

    2.479 inches minimum and 2.510 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac all locations and 35.0 amperes dc all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Test Data Document

    mil-prf-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...