AP16-1-61-252

Circuit Breakers

CIRCUIT BREAKER

AP16-1-61-252

5925-01-543-8270

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    1.562 inches maximum

  • Mounting Surface To Terminal End Distance

    1.605 inches nominal

  • Switch Voltage Rating And Type In Volts

    240.0 ac

  • Internal Trip Release Configuration

    relay trip all locations

  • Switch Terminal Type

    screw

  • External Actuator Linkage Arrangement

    one and two linked

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac all locations

  • Case Material

    plastic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Mounting Facility Type And Quantity

    1 unthreaded hole

  • Unthreaded Mounting Hole Diameter

    0.391 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 100 pct all locations

  • Body Style

    multipole-single actuator type

  • Body Width

    0.656 inches maximum

  • Bushing Length

    0.625 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Length

    0.625 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    4 screw

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Inclosure Protection Type For Which Designed

    moisture resistant and vibration resistant and shock resistant

  • Center To Center Distance Between Terminals Parallel To Width

    0.875 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Actuator Position Designation

    at each pole

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...