M39019/01-248

Circuit Breakers

CIRCUIT BREAKER

M39019/01-248

5925-01-548-6858

5925 - Circuit Breakers

Engineered Air Systems Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    2a single pole type

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Body Length

    1.562 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Iii End Item Identification

    pumping assembly,flammable liquid, bu nsn 4320-01-524-4446

  • Mounting Surface To Terminal End Distance

    1.700 inches maximum

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and 50.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac and 500.0 dc single location

  • Trip Release Method

    magnetic single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.375 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant and vibration resistant and moisture resistant and shock resistant and salt spray proof

  • Frequency In Hertz

    400.0 single location

  • Terminal Type And Quantity

    2 wire hook

  • Body Width

    0.625 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac and 10.0 amperes dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.950 maximum at 200 pct single location

  • Iii Unpackaged Unit Weight

    50.0 grams

  • Test Data Document

    81349-mil-c-39019 specification

  • Thread Series Designator

    unef

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...