GH3-G3-NU-0010-03B

Circuit Breakers

CIRCUIT BREAKER

GH3-G3-NU-0010-03B

5925-01-552-5336

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    fungus resistant and humidity resistant and shock resistant and vibration resistant

  • Internal Trip Release Configuration

    series trip all locations

  • Center To Center Distance Between Terminals Parallel To Length

    5.000 inches nominal

  • Special Features

    operating temperature range minus 40.0 to plus 85.0 degrees c; voltage rating 251.0 to 600.0 volts ac

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.687 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • End Item Identification

    radar tps-77

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Mounting Facility Type And Quantity

    4 slot

  • Mounting Slot Width

    0.203 inches nominal

  • Body Width

    4.125 inches nominal

  • Reset Method

    manual

  • Body Height

    3.125 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Boss Height

    0.250 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Body Length

    6.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct all locations and 0.600 maximum at 200 pct all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...