IPAH-II-I-61F-15.0-01

Circuit Breakers

CIRCUIT BREAKER

IPAH-II-I-61F-15.0-01

5925-01-554-2831

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Part Name Assigned By Controlling Agency

    ipa magnetic circuit breaker

  • Trip Release Method

    thermal-magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Special Features

    rated current 15 amps; moisture, salt, shock and vibration resistant; flywheel construction

  • Switch Location And Position Designation

    external at each pole

  • Internal Trip Release Configuration

    series trip all locations

  • Reset Method

    manual

  • Pole Quantity

    2

  • Body Width

    1.295 inches maximum

  • Trip Release Ambient Temp Rating

    -40.0 deg celsius minimum all locations and 85.0 deg celsius maximum all locations

  • Mounting Facility Type And Quantity

    4 threaded stud

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free