NSN: 5905-00-577-3956

Resistors

RESISTOR,THERMAL

5905 - Resistors

RESISTOR,THERMAL

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Resistance Tolerance At A Specified Temp In Percent

    -8.0/+8.0 2nd resistance-temperature point

  • Zero Power Resistance At Specified Temp

    2.2 kilohms 4th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    -25.0 deg celsius 4th resistance-temperature point

  • Maximum Operating Temp

    150.0 deg celsius

  • Body Outside Diameter

    0.125 inches minimum and 0.135 inches maximum

  • Temp Points For Resistance Readings At Zero Power

    125.0 deg celsius 9th resistance-temperature point

  • Zero Power Resistance Tolerance In Percent At Reference Temp

    -5.0/+5.0

  • Zero Power Resistance At Specified Temp

    1.6 kilohms 2nd resistance-temperature point

  • Zero Power Resistance

    3.300 kilohms

  • Temp Points For Resistance Readings At Zero Power

    50.0 deg celsius 6th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -5.3/+5.3 5th resistance-temperature point

  • Ambient Temp At Full Rated Power

    100.0 deg celsius

  • Zero Power Resistance At Specified Temp

    1.8 kilohms 3rd resistance-temperature point

  • Zero Power Resistance At Specified Temp

    6.6 kilohms 9th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    75.0 deg celsius 7th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    -50.0 deg celsius 3rd resistance-temperature point

  • Terminal Surface Treatment

    tin

  • Resistance Tolerance At A Specified Temp In Percent

    -6.6/+6.6 6th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -9.2/+9.2 9th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    -75.0 deg celsius 1st resistance-temperature point

  • Terminal Diameter

    0.025 inches nominal

  • Resistance Tolerance At A Specified Temp In Percent

    -6.7/+6.7 4th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -8.3/+8.3 1st resistance-temperature point

  • Body Length

    0.391 inches minimum and 0.421 inches maximum

  • Resistance Tolerance At A Specified Temp In Percent

    -7.2/+7.2 7th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    0.0 deg celsius 5th resistance-temperature point

  • Style Designator

    rod

  • Terminal Type And Quantity

    2 wire lead

  • Reliability Indicator

    not established

  • Maximum Power Dissipation Rating

    125.00 milliwatts

  • Thermal Time Constant In Seconds

    34.8

  • Resistance Tolerance At A Specified Temp In Percent

    -8.5/+8.5 8th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -7.4/+7.4 3rd resistance-temperature point

  • Zero Power Resistance At Specified Temp

    1.4 kilohms 1st resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    -65.0 deg celsius 2nd resistance-temperature point

  • Inclosure Type

    encapsulated

  • Zero Power Resistance At Specified Temp

    4.7 kilohms 7th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    4.0 kilohms 6th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    2.7 kilohms 5th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    7.4 kilohms 10th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -10.1/+10.1 10th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    150.0 deg celsius 10th resistance-temperature point

  • Zero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius

    0.70

  • Temp Points For Resistance Readings At Zero Power

    100.0 deg celsius 8th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    5.5 kilohms 8th resistance-temperature point

  • Terminal Length

    1.375 inches minimum and 1.625 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...