NSN: 5905-00-812-4939
Resistors
RESISTOR,THERMAL
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Ambient Temp At Full Rated Power
125.0 deg celsius
 - 
                                    
Resistance Tolerance At A Specified Temp In Percent
-10.0/+10.0 all resistance-temperature points
 - 
                                    
Zero Power Resistance
4.600 kilohms
 - 
                                    
Maximum Current Rating
25.00 amperes
 - 
                                    
Zero Power Resistance Tolerance In Percent At Reference Temp
-10.0/+10.0
 - 
                                    
Thermal Time Constant In Seconds
60.0
 - 
                                    
Temp Points For Resistance Readings At Zero Power
54.4 deg celsius 4th resistance-temperature point
 - 
                                    
Zero Power Resistance At Specified Temp
68.6 ohms 3rd resistance-temperature point
 - 
                                    
Temp Points For Resistance Readings At Zero Power
18.3 deg celsius 3rd resistance-temperature point
 - 
                                    
Zero Power Resistance At Specified Temp
16.1 kilohms 1st resistance-temperature point
 - 
                                    
Terminal Length
1.375 inches nominal
 - 
                                    
Zero Power Resistance At Specified Temp
1.6 kilohms 2nd resistance-temperature point
 - 
                                    
Terminal Diameter
0.020 inches nominal
 - 
                                    
Power Dissipation Constant In Milliwatts Per Deg Celsius
5.5
 - 
                                    
Maximum Operating Temp
200.0 deg celsius
 - 
                                    
Reference Temp In Deg Celsius
25.0
 - 
                                    
Maximum Power Dissipation Rating
2.25 watts
 - 
                                    
Style Designator
rod
 - 
                                    
Terminal Type And Quantity
2 wire lead
 - 
                                    
Temp Points For Resistance Readings At Zero Power
-51.1 deg celsius 1st resistance-temperature point
 - 
                                    
Reliability Indicator
not established
 - 
                                    
Body Length
0.906 inches nominal
 - 
                                    
Temp Points For Resistance Readings At Zero Power
-17.8 deg celsius 2nd resistance-temperature point
 - 
                                    
Temp Points For Resistance Readings At Zero Power
93.3 deg celsius 5th resistance-temperature point
 - 
                                    
Inclosure Type
encapsulated
 - 
                                    
Body Outside Diameter
0.219 inches nominal
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    