NSN: 5905-00-939-1946
Resistors
RESISTOR,THERMAL
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Temp Points For Resistance Readings At Zero Power125.0 deg celsius 4th resistance-temperature point 
- 
                                    Zero Power Resistance Tolerance In Percent At Reference Temp-10.0/+10.0 
- 
                                    Thermal Time Constant In Seconds60.0 
- 
                                    Temp Points For Resistance Readings At Zero Power50.0 deg celsius 2nd resistance-temperature point 
- 
                                    Body Outside Diameter0.200 inches nominal 
- 
                                    Maximum Operating Temp150.0 deg celsius 
- 
                                    Zero Power Resistance At Specified Temp675.0 ohms 1st resistance-temperature point 
- 
                                    Zero Power Resistance At Specified Temp1.8 kilohms 2nd resistance-temperature point 
- 
                                    Ambient Temp At Full Rated Power100.0 deg celsius 
- 
                                    Temp Points For Resistance Readings At Zero Power150.0 deg celsius 5th resistance-temperature point 
- 
                                    Body Length0.585 inches nominal 
- 
                                    Zero Power Resistance At Specified Temp2.9 kilohms 4th resistance-temperature point 
- 
                                    Zero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius0.70 
- 
                                    Resistance Tolerance At A Specified Temp In Percent-10.0/+10.0 all resistance-temperature points 
- 
                                    Zero Power Resistance At Specified Temp2.5 kilohms 3rd resistance-temperature point 
- 
                                    Temp Points For Resistance Readings At Zero Power100.0 deg celsius 3rd resistance-temperature point 
- 
                                    Zero Power Resistance1.500 kilohms 
- 
                                    Inclosure Typeencapsulated 
- 
                                    Reliability Indicatornot established 
- 
                                    Terminal Type And Quantity2 wire lead 
- 
                                    Terminal Length1.500 inches nominal 
- 
                                    Style Designatorrod 
- 
                                    Zero Power Resistance At Specified Temp3.1 kilohms 5th resistance-temperature point 
- 
                                    Maximum Power Dissipation Rating250.00 milliwatts 
- 
                                    Terminal Diameter0.025 inches nominal 
- 
                                    Temp Points For Resistance Readings At Zero Power-75.0 deg celsius 1st resistance-temperature point 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    