NSN: 5905-01-085-2265
Resistors
RESISTOR,VARIABLE,NONWIRE WOUND,NONPRECISION
RESISTOR,VARIABLE,NONWIRE WOUND,NONPRECISION
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Actuator Travel Control Featurestops 
- 
                                    Mounting Methodterminal 
- 
                                    Body Length0.190 inches nominal 
- 
                                    Maximum Starting Torque5.00 inch-ounces 
- 
                                    Center To Center Distance Between Terminals0.200 inches nominal 
- 
                                    Power Dissipation Rating Per Section In Watts0.5 free air single section 
- 
                                    Actuator Typeflush drive with slot-hole 
- 
                                    Terminal Locationlower adjacent side two rows 
- 
                                    Effective Electrical Rotation In Deg Angular Rotation280.0 nominal 
- 
                                    Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power125.0 single section 
- 
                                    Body Height0.375 inches nominal 
- 
                                    Reliability Indicatornot established 
- 
                                    Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius-100.0/+100.0 single section 
- 
                                    Electrical Resistance Per Section50.000 kilohms single section 
- 
                                    Ambient Temp In Deg Celsius Per Section At Full Rated Power85.0 single section 
- 
                                    Body Width0.375 inches nominal 
- 
                                    Standard Taper Curve Per Sectiona single section 
- 
                                    Resistance Tolerance Per Section In Percent-10.0/+10.0 single section 
- 
                                    Terminal Type And Quantity3 pin 
- 
                                    Center To Center Distance Between Terminal Rows0.100 inches nominal 
- 
                                    Terminal Length0.200 inches minimum 
- 
                                    Rotary Actuator Travel In Angular Deg310.0 nominal 
- 
                                    Body Stylerectangular 
- 
                                    Section Quantity1 
- 
                                    Maximum Running Torque5.00 inch-ounces 
- 
                                    Center To Center Distance Between Center Terminal And Outside Terminal0.100 inches nominal 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    