NSN: 5905-01-104-8540

Resistors

RESISTOR,THERMAL

5905 - Resistors

RESISTOR,THERMAL

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Style Designator

    bead

  • Terminal Type And Quantity

    2 wire lead

  • Reliability Indicator

    not established

  • Test Data Document

    82577-958043 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Inclosure Type

    encapsulated

  • Terminal Length

    2.875 inches minimum and 3.125 inches maximum

  • Zero Power Resistance At Specified Temp

    1.0 megohms 1st resistance-temperature point

  • Thermal Time Constant In Seconds

    10.0

  • Temp Points For Resistance Readings At Zero Power

    100.0 deg celsius 3rd resistance-temperature point

  • Zero Power Resistance Tolerance In Percent At Reference Temp

    -1.0/+1.0

  • Zero Power Resistance At Specified Temp

    678.3 ohms 3rd resistance-temperature point

  • Zero Power Resistance At Specified Temp

    185.9 ohms 4th resistance-temperature point

  • Power Dissipation Constant In Milliwatts Per Deg Celsius

    1.0

  • Zero Power Resistance At Specified Temp

    3.6 kilohms 2nd resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -1.0/+1.0 all resistance-temperature points

  • Zero Power Resistance

    10.000 kilohms

  • Temp Points For Resistance Readings At Zero Power

    -55.0 deg celsius 1st resistance-temperature point

  • Ambient Temp At Full Rated Power

    25.0 deg celsius

  • Reference Temp In Deg Celsius

    25.0

  • Temp Points For Resistance Readings At Zero Power

    150.0 deg celsius 4th resistance-temperature point

  • Terminal Diameter

    0.008 inches nominal

  • Body Outside Diameter

    0.095 inches maximum

  • Maximum Operating Temp

    150.0 deg celsius

  • Temp Points For Resistance Readings At Zero Power

    50.0 deg celsius 2nd resistance-temperature point

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...