NSN: 5915-00-007-7131

Technical Characteristics

  • Source Impedance Rating Per Function

    100.0 ohms 1st band pass

  • Specified Frequencies Of Discrimination Per Function

    478.30 kilohertz 2nd band pass and 477.525 kilohertz 2nd band pass and 478.35 kilohertz 2nd band pass and 479.125 kilohertz 2nd band pass

  • Load Impedance Per Function

    168.0 kilohms 1st band pass

  • Frequency Band Width Per Function

    478.30 kilohertz 2nd band pass and 478.35 kilohertz 2nd band pass

  • Load Impedance Per Function

    168.0 kilohms 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

  • Source Impedance Rating Per Function

    100.0 ohms 2nd band pass

  • Functional Terminal Type And Quantity

    2 pin ground 3rd function

  • Body Width

    1.120 inches maximum

  • Frequency Band Width Per Function

    478.00 kilohertz 1st band pass and 478.05 kilohertz 1st band pass

  • Specified Frequencies Of Discrimination Per Function

    478.00 kilohertz 1st band pass and 478.05 kilohertz 1st band pass and 477.225 kilohertz 1st band pass and 478.825 kilohertz 1st band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Unpackaged Unit Weight

    42.000 grams

  • Overall Height

    0.695 inches nominal

  • Operating Temp Range

    -20.0/+71.0 deg celsius

  • Reference Frequency Per Function

    478.325 single radio interference two phase to two phase

  • Body Length

    1.510 inches maximum

  • Functional Terminal Type And Quantity

    4 pin output 2nd function

  • Style Designator

    rectangular terminal/terminals on one surface

  • Body Material

    metal

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.5 maximum 1st band pass and 1.5 maximum 1st band pass and 30.0 minimum 1st band pass and 30.0 minimum 1st band pass

  • Reference Frequency Per Function

    478.025 single radio interference pulses per second

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.840 inches minimum and 0.860 inches maximum

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Body Height

    0.595 inches maximum

  • Mounting Facility Type And Quantity

    7 terminal

  • Functional Terminal Type And Quantity

    1 pin input 1st function

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.235 inches minimum and 1.245 inches maximum

  • Inclosure Type

    encased

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass and 1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...