NSN: 5915-00-020-5796
Filters and Networks
FILTER,BAND PASS
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Discrimination At Specified Frequencies Per Function In Decibels
3.0 nominal blank and 3.0 nominal blank and 60.0 nominal blank and 60.0 nominal blank
 - 
                                    
Functional Terminal Type And Quantity
1 pin input 1st function
 - 
                                    
Output Impedance Per Function W/Source Across Input
8.2 kilohms blank
 - 
                                    
Insertion Loss At Reference Frequency Per Function In Decibels
11.0 blank
 - 
                                    
Body Length
2.090 inches minimum and 3.010 inches maximum
 - 
                                    
Body Material
metal
 - 
                                    
Operating Temp Range
-0.0/+70.0 deg celsius
 - 
                                    
Frequency Band Width Per Function
249.95 kilohertz blank and 250.05 kilohertz blank
 - 
                                    
Style Designator
rectangular terminal/terminals on one surface
 - 
                                    
Body Height
1.990 inches minimum and 2.010 inches maximum
 - 
                                    
Principal Circuitry Type Per Function
crystal blank
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.395 inches minimum and 0.605 inches maximum
 - 
                                    
Overall Height
2.375 inches nominal
 - 
                                    
Mounting Facility Screw Thread Series Designator
unc
 - 
                                    
Functional Terminal Type And Quantity
2 pin ground 3rd function
 - 
                                    
Inclosure Type
hermetically sealed
 - 
                                    
Functional Terminal Type And Quantity
1 pin output 2nd function
 - 
                                    
Specified Frequencies Of Discrimination Per Function
249.95 kilohertz blank and 250.05 kilohertz blank and 249.85 kilohertz blank and 250.10 kilohertz blank
 - 
                                    
Mounting Facility Type And Quantity
4 threaded stud
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.145 inches minimum and 2.355 inches maximum
 - 
                                    
Body Width
1.395 inches minimum and 1.605 inches maximum
 - 
                                    
Input Impedance Per Function W/Load
50.0 ohms blank
 - 
                                    
Reference Frequency Per Function
250.0 kilohertz blank
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    