NSN: 5915-01-119-2725
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Operating Current Rating Per Function In Amps
1.0 5th radio interference
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
 - 
                                    
Overall Length
181.6 millimeters nominal
 - 
                                    
Load Impedance Per Function
50.0 ohms 2nd radio interference
 - 
                                    
Body Surface Treatment
tin
 - 
                                    
Special Features
8 functions
 - 
                                    
Operating Current Rating Per Function In Amps
1.0 6th radio interference
 - 
                                    
Maximum Voltage Drop Per Function
240.0 millivolts dc 1st radio interference
 - 
                                    
Output Terminal Identification
ms27468t17b35sa
 - 
                                    
Mounting Facility Type And Quantity
4 threaded hole
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
 - 
                                    
Mounting Slot Width
6.35 millimeters nominal
 - 
                                    
Body Height
75.0 millimeters nominal
 - 
                                    
Load Impedance Per Function
50.0 ohms 3rd radio interference
 - 
                                    
Maximum Voltage Drop Per Function
240.0 millivolts dc 2nd radio interference
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
 - 
                                    
Maximum Voltage Drop Per Function
240.0 millivolts dc 3rd radio interference
 - 
                                    
Output Terminal Manufacturer Code
96906
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
 - 
                                    
Maximum Voltage Drop Per Function
240.0 millivolts dc 4th radio interference
 - 
                                    
Functional Terminal Type And Quantity
8 threaded stud input 1st function
 - 
                                    
Body Width
150.0 millimeters nominal
 - 
                                    
Maximum Voltage Drop Per Function
240.0 millivolts dc 5th radio interference
 - 
                                    
Maximum Voltage Drop Per Function
240.0 millivolts dc 6th radio interference
 - 
                                    
Mounting Facility Screw Thread Series Designator
iso s
 - 
                                    
Body Length
150.0 millimeters nominal
 - 
                                    
Operating Current Rating Per Function In Amps
5.0 3rd radio interference
 - 
                                    
Inclosure Type
encased
 - 
                                    
Operating Current Rating Per Function In Amps
5.0 4th radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
24.0 volts dc 1st radio interference 1st function
 - 
                                    
Load Impedance Per Function
50.0 ohms 4th radio interference
 - 
                                    
Overall Height
97.0 millimeters nominal
 - 
                                    
Operating Voltage Rating And Type Per Function
24.0 volts dc 2nd radio interference 2nd function
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
 - 
                                    
Load Impedance Per Function
50.0 ohms 5th radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
24.0 volts dc 3rd radio interference 3rd function
 - 
                                    
Operating Current Rating Per Function In Amps
20.0 1st radio interference
 - 
                                    
Mounting Facility Type And Quantity
2 slot
 - 
                                    
Operating Voltage Rating And Type Per Function
24.0 volts dc 4th radio interference 4th function
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
130.0 millimeters nominal
 - 
                                    
Maximum Dielectric Withstanding Dc Voltage
100.0 volts at sea level
 - 
                                    
Style Designator
rectangular terminal/terminals on two surfaces
 - 
                                    
Operating Voltage Rating And Type Per Function
24.0 volts dc 5th radio interference 5th function
 - 
                                    
Operating Voltage Rating And Type Per Function
24.0 volts dc 6th radio interference 6th function
 - 
                                    
Load Impedance Per Function
50.0 ohms 6th radio interference
 - 
                                    
Functional Terminal Type And Quantity
1 connector, receptacle output 2nd function
 - 
                                    
Load Impedance Per Function
50.0 ohms 1st radio interference
 - 
                                    
Operating Current Rating Per Function In Amps
5.0 2nd radio interference
 - 
                                    
Operating Temp Range
-55.0/+85.0 deg celsius
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    