NSN: 5915-01-148-3295

Technical Characteristics

  • Inclosure Type

    encased

  • Functional Terminal Type And Quantity

    2 connector, receptacle input 1st function and 2 pin input 1st function

  • Maximum Voltage Drop Per Function

    20.0 millivolts ac 4th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Maximum Voltage Drop Per Function

    10.0 millivolts ac 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Current Rating Per Function In Amps

    0.5 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Body Width

    4.900 inches maximum

  • Operating Voltage Rating And Type Per Function

    28.0 volts dc 6th radio interference 6th function

  • Maximum Voltage Drop Per Function

    210.0 millivolts ac 3rd radio interference

  • Maximum Voltage Drop Per Function

    150.0 millivolts dc 6th radio interference

  • Nominal Thread Size

    0.164 inches

  • Mounting Facility Screw Thread Series Designator

    unc

  • Maximum Voltage Drop Per Function

    210.0 millivolts ac 2nd radio interference

  • Body Material

    aluminum

  • Operating Voltage Rating And Type Per Function

    50.0 volts ac 4th radio interference 4th function

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Maximum Temp Rise

    40.0 deg celsius

  • Unpackaged Unit Weight

    2.980 pounds

  • Style Designator

    rectangular terminal/terminals on two surfaces

  • Functional Terminal Type And Quantity

    1 pin ground 3rd function

  • Maximum Voltage Drop Per Function

    210.0 millivolts ac 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Overall Length

    5.500 inches maximum

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    168.0 volts ac 5th radio interference 5th function

  • Special Features

    18 functions; 26 dummy terminals

  • Body Length

    5.500 inches maximum

  • Operating Current Rating Per Function In Amps

    6.0 4th radio interference

  • Operating Voltage Rating And Type Per Function

    168.0 volts ac 3rd radio interference 3rd function

  • Operating Current Rating Per Function In Amps

    6.0 3rd radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    4.275 inches nominal

  • Overall Height

    3.734 inches maximum

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.875 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Operating Current Rating Per Function In Amps

    6.0 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    168.0 volts ac 2nd radio interference 2nd function

  • Functional Terminal Type And Quantity

    18 pin output 2nd function

  • Operating Temp Range

    -55.0/+95.0 deg celsius

  • Operating Voltage Rating And Type Per Function

    168.0 volts ac 1st radio interference 1st function

  • Body Surface Treatment

    tin

  • Operating Current Rating Per Function In Amps

    6.0 1st radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Body Height

    3.000 inches maximum

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 6th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...