NSN: 5915-01-158-4803

Filters and Networks

FILTER,BAND PASS

5915 - Filters and Networks

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 4th band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 5th band pass and 3.0 minimum 1st band pass and 3.0 minimum 3rd band pass and 3.0 minimum 4th band pass and 3.0 minimum 2nd band pass and 30.0 maximum 4th band pass

  • Body Length

    3.035 inches maximum

  • Specified Frequencies Of Discrimination Per Function

    19.728 kilohertz 1st band pass and 18.96 kilohertz 1st band pass and 18.768 kilohertz 1st band pass and 19.936 kilohertz 1st band pass

  • Style Designator

    rectangular terminal/terminals on one surface

  • Reference Frequency Per Function

    21.376 single radio interference two phase to two phase

  • Frequency Band Width Per Function

    40.784 kilohertz 5th band pass and 42.416 kilohertz 5th band pass

  • Load Impedance Per Function

    100.0 kilohms 2nd band pass

  • Unpackaged Unit Weight

    6.000 ounces

  • Reference Frequency Per Function

    26.128 single radio interference hertz

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 5th band pass

  • Specified Frequencies Of Discrimination Per Function

    25.60 kilohertz 4th band pass and 26.64 kilohertz 4th band pass and 25.344 kilohertz 4th band pass and 26.912 kilohertz 4th band pass

  • Load Impedance Per Function

    100.0 kilohms 3rd band pass

  • Frequency Band Width Per Function

    18.96 kilohertz 1st band pass and 19.728 kilohertz 1st band pass

  • Load Impedance Per Function

    100.0 kilohms 4th band pass

  • Operating Temp Range

    -29.0/+85.0 deg celsius

  • Specified Frequencies Of Discrimination Per Function

    40.784 kilohertz 5th band pass and 40.352 kilohertz 5th band pass and 42.416 kilohertz 5th band pass and 42.848 kilohertz 5th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 1st band pass

  • Frequency Band Width Per Function

    25.60 kilohertz 4th band pass and 26.64 kilohertz 4th band pass

  • Load Impedance Per Function

    100.0 kilohms 5th band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Functional Terminal Type And Quantity

    5 pin output 2nd function

  • Inclosure Type

    hermetically sealed

  • Body Height

    0.580 inches maximum

  • Source Impedance Rating Per Function

    1.0 kilohms 2nd band pass

  • Overall Height

    0.750 inches maximum

  • Reference Frequency Per Function

    19.344 single radio interference pulses per second

  • Body Material

    metal

  • Source Impedance Rating Per Function

    1.0 kilohms 3rd band pass

  • Reference Frequency Per Function

    41.6 single radio interference three phase to two phase

  • Body Width

    1.875 inches maximum

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 1st band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 4th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 5th band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 2nd band pass

  • Reference Frequency Per Function

    23.632 single radio interference two phase to three phase

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 3rd band pass

  • Specified Frequencies Of Discrimination Per Function

    20.736 kilohertz 2nd band pass and 20.944 kilohertz 2nd band pass and 21.792 kilohertz 2nd band pass and 22.032 kilohertz 2nd band pass

  • Functional Terminal Type And Quantity

    1 pin input 1st function

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 maximum 5th band pass

  • Mounting Facility Type And Quantity

    12 pin

  • Frequency Band Width Per Function

    20.944 kilohertz 2nd band pass and 21.792 kilohertz 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 3rd band pass

  • Specified Frequencies Of Discrimination Per Function

    22.928 kilohertz 3rd band pass and 23.168 kilohertz 3rd band pass and 24.096 kilohertz 3rd band pass and 24.352 kilohertz 3rd band pass

  • Body Surface Treatment

    tin

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Special Features

    five filtered functions

  • Load Impedance Per Function

    100.0 kilohms 1st band pass

  • Functional Terminal Type And Quantity

    1 pin ground 3rd function

  • Frequency Band Width Per Function

    23.168 kilohertz 3rd band pass and 24.096 kilohertz 3rd band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...