NSN: 5915-01-254-0619

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

5915 - Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Overall Length

    0.617 inches nominal

  • Body Outside Diameter

    0.040 inches nominal

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • End Item Identification

    alm/226 hts f

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference .

  • Load Impedance Per Function

    50.0 ohms 1st radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 5th radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 6th radio interference .

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Input Terminal Manufacturer Code

    06424

  • ~1

    .

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 5th radio interference and 200.0 volts dc 5th radio interference

  • Body Material

    metal

  • Body Surface Treatment

    tin

  • Precious Material And Location

    filter surfaces silver and contact surfaces gold

  • Precious Material

    silver and gold

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference .

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference .

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference .

  • Load Impedance Per Function

    50.0 ohms 4th radio interference .

  • Load Impedance Per Function

    50.0 ohms 5th radio interference .

  • Load Impedance Per Function

    50.0 ohms 6th radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference .

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference .

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Input Terminal Identification

    sma-receptacle

  • Inclosure Type

    encased

  • Mounting Facility Type And Quantity

    26 terminal

  • Functional Terminal Type And Quantity

    1 connector, receptacle input .

  • Functional Terminal Type And Quantity

    25 friction w/grounding strap and pin output .

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 1st radio interference and 200.0 volts dc 1st radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 2nd radio interference and 200.0 volts dc 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 3rd radio interference and 200.0 volts dc 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 4th radio interference and 200.0 volts dc 4th radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 6th radio interference and 200.0 volts dc 6th radio interference

  • Style Designator

    37 round terminal/terminals on opposite surface

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...