NSN: 5915-01-312-3421
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-f-15733 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Maximum Dielectric Withstanding Dc Voltage
1.0 kilovolts at sea level
-
Body Height
2.220 inches minimum and 2.280 inches maximum
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function and 400.0 volts dc 1st radio interference 1st function
-
Maximum Voltage Drop Per Function
1.15 volts ac 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
6.230 inches minimum and 6.270 inches maximum
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Specification/Standard Data
81349-mil-f-15733/75 government specification
-
Thread Tolerance Class
2a external
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Unpackaged Unit Weight
6.870 pounds
-
Features Provided
nut and washer
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Overall Length
8.220 inches maximum
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function and 400.0 volts dc 2nd radio interference 2nd function
-
Mounting Slot Width
0.250 inches nominal
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Body Material
metal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Maximum Voltage Drop Per Function
1.15 volts ac 1st radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function and 400.0 volts dc 3rd radio interference 3rd function
-
~1
data on certain environmental and performanc
-
Operating Current Rating Per Function In Amps
50.0 1st radio interference
-
Operating Current Rating Per Function In Amps
50.0 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Operating Current Rating Per Function In Amps
50.0 3rd radio interference
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Maximum Temp Rise
35.0 deg celsius
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Special Features
three filtered functions
-
Vibration Resistance Range In Hertz
+10.0/+55.0
-
Functional Terminal Type And Quantity
3 threaded stud output 2nd function
-
Maximum Voltage Drop Per Function
1.15 volts ac 3rd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Mounting Facility Screw Thread Series Designator
unc
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Functional Terminal Type And Quantity
3 threaded stud input 1st function
-
Mounting Facility Type And Quantity
2 slot
-
Inclosure Type
hermetically sealed
-
Body Width
6.720 inches minimum and 6.780 inches maximum
-
Mounting Facility Type And Quantity
4 threaded stud
-
Body Length
6.910 inches minimum and 6.940 inches maximum
-
Nominal Thread Size
0.250 inches
Related Parts by Category