NSN: 5925-00-008-0535

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    1a single pole type

  • Bushing Length

    0.219 inches minimum and 0.281 inches maximum

  • Body Length

    0.719 inches minimum and 0.781 inches maximum

  • Body Width

    0.531 inches minimum and 0.593 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.672 inches minimum and 0.734 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.919 inches minimum and 1.981 inches maximum

  • Arc Quenching Method

    air

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac and 28.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.469 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 20.000 maximum at 200 pct single location

  • Frequency In Hertz

    400.0

  • Unpackaged Unit Weight

    38.0 grams

  • Case Material

    plastic

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes ac and 4.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac and 5000.0 dc single location

  • Trip Release Method

    thermal single location

  • Trip Release Characteristic

    time delay single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and vibrationproof

  • Trip Release Ambient Temp Rating

    25.0 deg celsius maximum single location

  • Thread Series Designator

    uns

  • Terminal Type And Quantity

    2 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...