NSN: 5925-00-008-0550
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc single location
 - 
                                    
Mounting Surface To Terminal End Distance
1.365 inches minimum and 1.375 inches maximum
 - 
                                    
Overall Length
1.995 inches minimum and 2.005 inches maximum
 - 
                                    
Body Width
0.775 inches minimum and 0.786 inches maximum
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Trip Release Method
thermal single location
 - 
                                    
Inclosure Protection Type For Which Designed
hermetically sealed
 - 
                                    
Pole Quantity
1
 - 
                                    
Case Material
metal
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Unthreaded Mounting Hole Diameter
0.215 inches minimum and 0.225 inches maximum
 - 
                                    
Mounting Facility Type And Quantity
2 unthreaded hole
 - 
                                    
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.673 inches minimum and 0.683 inches maximum
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.557 inches minimum and 1.567 inches maximum
 - 
                                    
Body Style
single pole type
 - 
                                    
Trip Release Characteristic
instantaneous single location
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
24.0 dc single location
 - 
                                    
Reset Method
automatic
 - 
                                    
Terminal Type And Quantity
2 threaded stud
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    