NSN: 5925-00-009-3005

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Current Rating And Type In Amps

    5.0 ac and 5.0 dc

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 4.000 maximum at 200 pct all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Unpackaged Unit Weight

    5.000 ounces

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Center To Center Distance Between Terminals Parallel To Length

    1.560 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    2.093 inches nominal

  • Storage Type

    general purpose warehouse

  • Switch Location And Position Designation

    internal at pole two

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Terminal Type And Quantity

    4 tab, solder lug

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Width

    1.500 inches nominal

  • External Actuator Linkage Arrangement

    one and two linked

  • Case Material

    plastic

  • Boss Height

    0.130 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    19.0 amperes ac all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Arc Quenching Method

    magnetic blowout

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...