NSN: 5925-00-009-6791

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Switch Terminal Type

    turret

  • Boss Height

    0.150 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Body Width

    2.280 inches nominal

  • Body Length

    2.530 inches nominal

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Current Rating And Type In Amps

    2.5 ac and 1.0 dc

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Unpackaged Unit Weight

    14.000 ounces

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.500 minimum at 200 pct all locations and 8.500 maximum at 200 pct all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    external at pole one

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Mounting Surface To Terminal End Distance

    2.480 inches nominal

  • Manual Actuator Type And Quantity

    3 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...